Purified water is produced based on reverse osmosis technology,due to low requirements for feed water,tap water or ground water is usually available for water sources.
What is RO ?
Natural osmosis occurs when a semi-permeable membrane separates two fluids of different salinity. The fluid with the lower salinity will pass through the membrane until the salt solution becomes equal on both sides of the membrane.
Reverse osmosis (RO)is the reverse of normal osmosis process,it occurs when the water is forced by pressure from higher salinity solution to permeated water side across a semi-permeable membrane,the memebrane allows the passage of water, but not impurities, organics, ions etc. The rejection rate can usually reach above 97%, and the highest will reach 99.8%.
Two Stage RO
RO can be used as one or two-stage process, depending on conditions of raw water, in the two stage process, the permeated water from first stage is sent directly to the second RO, producing a higher purity water than is possible with one stage alone.
Generally, if the electrical conductivity of raw water is above 400μs/cm, to meet the national standards, the purified water will be produced through two stage RO system,if under 400μs/cm, one stage RO system is available.
The contaminants such as inorganic salt, bacterias,virus, glucides,amino acid will be removed through RO system, the final permeated water can be fully comply with the national standards of GB17323-1998、GB17324-1998 etc.
RO system can be widely used in various water plants, pharmaceutical and biotechnology processes, chemical industry, food & beverage production, laboratory, manufacturing industry as well as brackish water desalination, etc.
The Operating Conditions of One Stage RO System
Item |
Run Conditions |
Item |
Run Conditions |
Operating Pressure of Pretreatment System |
0.3MPa |
Operating Pressure of RO System |
1.05MPa |
Operating Temperature |
5℃~40℃, |
PH of feed water for RO system |
4~9 |
Control Mode of Main System |
manual、automatic (optional) |
Power Requirements |
Three-phase four-wire AC380V/50HZ |
Control Mode of Pretreatment System |
Manual valves、fully automatic solenoid control valves, fully automatic multiport control valves (optional) |
Spefications of JNB One Stage RO System
No |
Model |
Permeate Flow(t/h) |
Power Consumption(kw/h) |
Control Mode |
Specifications for RO Membranes |
1 |
JB-ROY300 |
0.3 |
2.5 |
manual、automatic (optional) |
ESPA4040 |
2 |
JB-ROY500 |
0.5 |
3.0 |
manual、automatic (optional) |
ESPA4040 |
3 |
JB-ROY750 |
0.75 |
3.0 |
manual、automatic (optional) |
ESPA4040 |
4 |
JB-ROY1000 |
1.0 |
3.5 |
manual、automatic (optional) |
ESPA4040 |
5 |
JB-ROY1500 |
1.5 |
4.5 |
manual、automatic (optional) |
ESPA4040 |
6 |
JB-ROY2000 |
2.0 |
5.5 |
manual、automatic (optional) |
ESPA4040 |
7 |
JB-ROY3000 |
3.0 |
6.5 |
manual、automatic (optional) |
ESPA4040 |
8 |
JB-ROY4000 |
4.0 |
7.5 |
manual、automatic (optional) |
ESPA4040 |
9 |
JB-ROY5000 |
5.0 |
8.5 |
manual、automatic (optional) |
ESPA4040 |
10 |
JB-ROY6000 |
6.0 |
9.5 |
manual、automatic (optional) |
ESPA4040、ESPA8040 (optional) |
11 |
JB-ROY8000 |
8.0 |
16.5 |
manual、automatic (optional) |
ESPA4040、ESPA8040 (optional) |
12 |
JB-ROY10000 |
10.0 |
17.5 |
manual、automatic (optional) |
ESPA4040、ESPA8040 (optional) |
Notes: Other permeate flow available on request